Now showing items 21-32 of 32

    • Assessment of Temperature Effects in Interior Orientation Parameters Calibration of Optoelectronic Devices 

      Starasotnikau, M. A. (БНТУ, 2020)
      A digital micromirror device (DMD) micromirrors periodic spatial structure is a measuring scale in interior orientation parameters calibration of optoelectronic devices problems, when using a DMD as a testobject. It is important that DMD micromirrors periodic spatial structure remains constant. Change in a DMD micromirrors spatial structure may occur due to heating. In addition ...
      2020-06-30
    • System of Laser Monitoring of Water Pollution with Application of Relative Description of Signal Shape 

      Alekseev, V. A.; Yuran, S. I.; Usoltsev, V. P.; Shulmin, D. N. (БНТУ, 2020)
      As a rule, the wastewater treatment system is not designed to filter substances formed, as a result of beyond design basis accident. The nature of the beyond design basis accident is associated with the shortterm appearance of a clot of these substances in wastewater, determined by the volume of the substance storage tank. Therefore, a rational approach is to divert this portion ...
      2020-06-30
    • System for Assessing the Effectiveness of Temporary Blinding Devices 

      Terekhova, M.; Rudikov, S.; Shumski, A.; Shkadarevich, A. (БНТУ, 2020)
      The development of non-lethal weapons and, in particular, temporary blinding devices is associated with problem of choosing boundaries of effectiveness. The aim of present work is determination of criteria for estimation of the effects of visual jamming devices action on the naked eye. The present-day scoring system used for effectiveness estimation of laser temporary blinding ...
      2020-06-29
    • Surface Eddy Current Probes: Excitation Systems of the Optimal Electromagnetic Field (Review) 

      Halchenko, V. Ya.; Trembovetskaya, R. V.; Tychkov, V. V. (БНТУ, 2020)
      Development of technical tools with improved metrological and operational characteristics is the actual problem of the eddy current testing. Ensuring the optimal distribution of the electromagnetic excitation field in the testing zone carries out confident detection of the defects and determination of their geometrical parameters by means of eddy current testing. The purpose of ...
      2020-06-29
    • Методика снижения потерь информации в асинхронном двоичном однофотонном канале связи с приёмником на основе счётчика фотонов 

      Тимофеев, А. М. (БНТУ, 2020)
      Приёмные модули однофотонных систем связи при измерении маломощных оптических сигналов должны обеспечивать наименьшие потери передаваемой информации. В этой связи целесообразно использовать счётчики фотонов, которые являются высокочувствительными, однако характеризуются ошибками регистрации данных. Цель работы – разработать методику определения интенсивности регистрируемого ...
      2020-03-17
    • Features of Аpplication of a Сombined Аpproach to the Еvaluation of the Мeasurement Results Uncertainty 

      Serenkov, P. S.; Hurevich, V. L.; Tolochko, T. K. (БНТУ, 2020)
      The article exposes description of features of the combined approach application to the evaluation of measurement results uncertainty. The aim of this work is the justification and development of new science-driven approaches to achieve maximum efficacy of measurements on the criteria "accuracy/costs" at the stated level of confidence. It provides theoretical base for correctness ...
      2020-03-17
    • The Dynamic Behaviour of Capacitive Humidity Sensors 

      Majewski, J. (БНТУ, 2020)
      The sensor design features and the sensing material properties which can influence the response time of the polymer-based capacitive humidity sensors are shortly discussed. The ways of specifying the dynamic properties of capacitive humidity sensors in technical data sheets by the leading companies on the market are briefly characterized and discussed. The schematic view and ...
      2020-03-17
    • Negative Ion Beam Emittance Calculations 

      Turek, M.; Wegierek, P. (БНТУ, 2020)
      Computer simulations are commonly used to support design and optimisation of powerful negative ion sources for the needs of future thermonuclear reactors like e. g. ITER. The aim of the paper was to study changes of produced beam quality (described by its emittance and brightness) with the geometry of the extraction system as well as extraction voltage. A two-dimensional ...
      2020-03-17
    • Измерительный преобразователь для ёмкостного сенсора воздушного зазора в гидрогенераторе 

      Левицкий, А. С.; Зайцев, Е. А.; Березниченко, В. А.; Сухорукова, А. Е. (БНТУ, 2020)
      Одним из важнейших параметров мощных гидрогенераторов является воздушный зазор между ротором и статором, и его отклонение от заданных норм является дефектом, который может привести к серьёзным авариям. Поэтому величину и форму зазора необходимо контролировать как во время осмотров, так и при эксплуатации машины. Целью данной работы являлась разработка вторичного измерительного ...
      2020-03-16
    • Математическая модель сенсора с открытой областью пространства 

      Джежора, А. А.; Завацкий, Ю. А.; Коваленко, А. В.; Науменко, А. М. (БНТУ, 2020)
      Для эффективного применения диэлектрометрических сенсоров большое значение имеет оптимизация конструктивных параметров сенсоров, таких как глубина проникновения электромагнитного поля, величина сигнала сенсора. Цель работы заключалась в построении математической модели сенсора с открытой областью пространства и расчёте его параметров. Представлены результаты расчёта основных ...
      2020-03-16
    • Afocal Mirror Systems with Small Axial Dimensions 

      Artioukhina, N. K.; Peroza, L. (БНТУ, 2020)
      The searching and designing new solutions for mirror systems, including afocal ones, has been studied for decades. In the design, it has always been difficult to combine optimization and cost. Nowadays, the problem remains relevant. The widespread use of mirror systems is due to some aspects: thermal stability, high resolution in a wide spectral range, and the absence of image ...
      2020-03-16
    • Dual Wavelength Chirped Pulse Regenerative Amplifier Based on Yb3+:LuAlO3 Crystal for Terahertz Applications 

      Rudenkov, A.; Kisel, V.; Yasukevich, A.; Hovhannesyan, K.; Petrosyan, A.; Kuleshov, N. (БНТУ, 2020)
      Compact diode-pumped chirped pulse regenerative amplifier systems with pulse repetition rate of hundreds kilohertz based on Yb3+-doped crystals are of practical importance for wide range of applications such as materials processing, medicine, scientific research, etc. The aim of this work was to study the Yb3+:LuAlO3 crystal based dual wavelength chirped pulse regenerative ...
      2020-03-16